XPA 2003C-70V, XPA 2003C-100V |
|
Audio |
Voltage gain | |
Channels 1 and 2 | 23x (27 dB) |
Channel 3 | |
XPA 2003C-70V | 57x (35 dB) |
XPA 2003C-100V | 81x (38 dB) |
Crosstalk | 75 dB (typical) @ 1 kHz |
CMRR | 75 dB (typical) @ 1 kHz |
|
Audio input |
Number/signal type | 3 balanced/unbalanced |
Connectors | (3) 3.5 mm captive screw connectors, 3 pole |
Impedance | >10k ohms unbalanced/balanced, DC coupled |
Nominal level | +4 dBu (1.23 Vrms), balanced |
Maximum level | +21 dBu (8.69 Vrms), balanced |
Input sensitivity | +4 dBu (1.23 Vrms) |
Input signal detection threshold | -40 dBu ±3 dB, balanced |
|
Audio output |
Number/signal type | |
XPA 2003C-70V | 2 channels, 4 or 8 ohms 1 channel, 70 V |
XPA 2003C-100V | 2 channels, 4 or 8 ohms 1 channel, 100 V |
Connectors | (1) 5 mm screw lock captive screw connector, 4 pole (1) 5 mm screw lock captive screw connector, 2 pole |
Load impedance | |
Channel 1 or 2 | 4 ohms minimum |
Channel 3 | |
XPA 2003C-70V | 25 ohms minimum |
XPA 2003C-100V | 50 ohms minimum |
Amplifier type | Class D |
Output power | |
Channel 1 or 2 (8 ohm) | 100 watts rms per channel, 1 kHz, 0.1% THD |
Channel 1 or 2 (4 ohm) | 200 watts rms per channel, 1 kHz, 0.1% THD |
Channel 3 | |
XPA 2003C-70V (70 V output) | 200 watts rms per channel, 70 V, 1 kHz, 0.1% THD |
XPA 2003C-100V (100 V output) | 200 watts rms per channel, 100 V, 1 kHz, 0.1% THD |
Frequency response | 20 Hz to 20 kHz, ±1 dB |
THD + Noise | |
Channel 1 or 2 | 0.1% @ 20 Hz to 20 kHz, 8 ohms, 3 dB below clipping |
Channel 3 | 0.1%, 1 kHz, 3 dB below clipping |
S/N | 100 dB, 20 Hz - 20 kHz, unweighted |
Damping factor | |
Channel 1 or 2 | >100 @ 8 ohms |
Channel 3 | |
XPA 2003C-70V | >100 @ 25 ohms |
XPA 2003C-100V | >100 @ 50 ohms |
High pass filter | |
XPA 2003C-70V | 80 Hz, 12 dB per octave rolloff for 70 V line output (switch selectable) |
XPA 2003C-100V | 80 Hz, 12 dB per octave rolloff for 100 V line output (switch selectable) |
|
Control/remote — amplifier |
Control port | (1) 3.5 mm captive screw connector, 2 pole |
Pin configurations | |
Standby power control (contact closure) | Pin 1 = GND, pin 2 = standby |
|
General |
Power | Internal
Input: 100-240 VAC, 50-60 Hz |
Power consumption at 115 VAC, 60 Hz | |
Typical (1/8 power) | |
XPA 2003C-70V | 4 ohms (x2) + 70 V: 122.4 watts 8 ohms (x2) + 70 V: 92.2 watts |
XPA 2003C-100V | 4 ohms (x2) + 100 V: 123.1 watts 8 ohms (x2) + 100 V: 94.4 watts |
Quiescent | |
XPA 2003C-70V | 28.9 watts |
XPA 2003C-100V | 28.1 watts |
Standby | <1 watt (triggered by contact closure or after 25 minutes [±5 minutes] with no signal) |
Power consumption at 230 VAC, 50 Hz | |
Typical (1/8 power) | |
XPA 2003C-70V | 4 ohms (x2) + 70 V: 122.4 watts 8 ohms (x2) + 70 V: 92.9 watts |
XPA 2003C-100V | 4 ohms (x2) + 100 V: 123.3 watts 8 ohms (x2) + 100 V: 95.3 watts |
Quiescent | |
XPA 2003C-70V | 29.8 watts |
XPA 2003C-100V | 28.6 watts |
Standby | <1 watt (triggered by contact closure or after 25 minutes [±5 minutes] with no signal) |
Temperature/humidity | Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing |
Cooling | Convection, no vents, with heat sinks on the sides |
Thermal dissipation at 115 VAC, 60 Hz | |
Standby | <1 watt (3 BTU/hr) |
Idle | |
XPA 2003C-70V | 28.9 watts (99 BTU/hr) |
XPA 2003C-100V | 28.1 watts (96 BTU/hr) |
1/8 power | |
XPA 2003C-70V | 4 ohms (x2) + 70 V: 47.4 watts (162 BTU/hr) 8 ohms (x2) + 70 V: 42.2 watts (144 BTU/hr) |
XPA 2003C-100V | 4 ohms (x2) + 100 V: 48.1 watts (164 BTU/hr) 8 ohms (x2) + 100 V: 44.4 watts (152 BTU/hr) |
Thermal dissipation at 230 VAC, 50 Hz | |
Standby | <1 watt (3 BTU/hr) |
Idle | |
XPA 2003C-70V | 29.8 watts (102 BTU/hr) |
XPA 2003C-100V | 28.6 watts (98 BTU/hr) |
1/8 power | |
XPA 2003C-70V | 4 ohms (x2) + 70 V: 47.4 watts (162 BTU/hr) 8 ohms (x2) + 70 V: 42.9 watts (146 BTU/hr) |
XPA 2003C-100V | 4 ohms (x2) + 100 V: 48.3 watts (165 BTU/hr) 8 ohms (x2) + 100 V: 45.3 watts (155 BTU/hr) |
Protection | Clip limiting, thermal, short circuit, DC output |
Indication | Limiter/Protect LED indicates the onset of clip limiting, thermal cycling, or a short circuit |
Mounting | |
Rack mount | Yes, with included mounting brackets |
Enclosure type | Metal |
Enclosure dimensions | 1.7" H x 17.4" W* x 12.0" D (1U high, full rack wide) (4.3 cm H x 44.2 cm W* x 30.5 cm D) *Width excludes rack ears. 19.0" (48.3 cm) W with rack ears. |
Product weight | 9.2 lbs (4.2kg) |
Shipping weight | 12 lbs (6 kg) |
Vibration | ISTA 1A in carton (International Safe Transit Association) |
Regulatory compliance | |
Safety | BSMI, CCC, CE, c-UL, GS, KC, PSE, S-Mark, UL Meets UL 60065, IEC 60065, and BSEN 60065 for AV equipment. |
EMI/EMC | CE, CISPR 22 Class B, CISPR 24, C-tick, EN55103-1, EN55103-2, FCC Class B, ICES, KCC, VCCI Class B |
Environmental | Complies with the appropriate requirements of ENERGY STAR® (ENERGY STAR qualified amplifier), EU code of conduct, RoHS, WEEE |
Warranty | 3 years parts and labor |